Above Measuring condition under temperature : 25~35℃ R.H. 25 ~75%.According to standard GB/T9396-1996  | ||||||
  | Model  | UGF-26008W-1  | ||||
1  | Type  | Dynamic Speaker  | ||||
2  | Dimension  | Outline Dimension Shall Be As Shown In Fig(1).  | ||||
3  | Weight  | Approx 4.5 Grams.  | ||||
4  | Magnet  | Material  | Nd-Fe-B  | |||
5  | Impedance  | 8  | ± 15% Ohm  | |||
6  | Power Rating  | Normal  | 1.0W  | Maximum  | 1.5W  | |
7  | FO  | 590±20% Hz  | ||||
8  | S.P.L.  | 93±3dB/1.0Watt 0.1Meter. At1000.1200.1500.2000Hz.  | ||||
Measurement Method Shown In Fig(2).  | ||||||
9  | Frequency Range  | F0~20,000Hz.Average SPL-10dB. Frequency Response Fig(3).  | ||||
10  | Distortion  | 5% Maximum At1000Hz. 1.0W  | ||||
11  | Abnormal Sound Test  | Must be Normal Tested by  | 2.83  | Volts.Sine wave for50~5kHz  | ||
12  | Polarity  | Diaphragm Shall Move Forward When Apply a Positive DC.  | ||||
Red“+”or“Marked” Terminal  | ||||||
13  | OperatingTemperature  | -20°C to +50°C  | ||||
14  | Storage Temperature  | -25°C to +55°C  | ||||
15  | Reliable Test  | |||||
After any following test leave speakers at room temperature for 1 hour, SPL shall not deviate by ± 3 db from initial value  | ||||||
15-1  | Load Test  | white noise for 96 hours at 1.0W input power.  | ||||
15-2  | High Temperature Test  | +55±2 °C 96hours  | ||||
15-3  | Low Temperature Test  | -20±2 °C96hours  | ||||
15-4  | Humidity Test  | +40±2 °C relative humidity 90~95%R.H 96hours  | ||||
15-5  | Vibration Test  | Frequency 30 ± 15 Hz, Amplitude 1.5 mm for 2 Hours per axis(x. y. z axis)  | ||||
15-6  | Temperature Cycle test  | 75 CM free falling on Concrete floor, 10 times.  | ||||
15-7  | Temperature Cycle test  | -25°C ~ + 65°C 5 Cycles Temperature test.  | ||||
16. Drawing(Fig1)   Unit: mm  Tolerance:±0.3mm

17.Frequency Resonance Fig (3).